Alternatively, a separate line with a higher cross-section can be installed. Especially Tree light fixtures have a higher power requirement that can lead to voltage drop on the 24V lines, and depending on the topology, the achievable line length can be significantly shorter.įor longer distances or higher loads, either use a separate power supply closer to the loads, or split the loads across multiple home runs. length of 500m applies to the communication lines of a Tree Branch, not to the line length of the 24V power supply. This connection is crucial for reliable data transmission. For this all power supply's GND (negative) have to be interconnected.

in a sub-panel, or if separate power supplies are used for lighting). This is necessary if more than one power supply is used. Within the enclosure, panel wire is also used for wiring.ĭevices that communicate with each other have to share a common GND. We recommend running one Tree cable from the panel per room and then branching off to the individual Tree devices in that room. For devices with higher power requirements such as Tree lighting products, the Tree cable also contains a pair of wires with 1.5mm² cross-section (AWG16) for power supply. The Loxone Tree cable is used for wiring, it contains the Tree communication lines as well as the lines for the 24VDC power supply in the corresponding colors. The following wiring topologies are possible, at a maximum length of 500m/1640ft: The following diagram shows the wiring of several Tree devices connected to two different Branches of a Tree Extension. There must be no connection between different Tree branches. Up to 50 Tree Devices can be connected to the Tree Interface of a Miniserver, or each of the two branches of a Tree Extension.

You can now proceed with pairing the Extensions. The Link interface is terminated at the last Extension using the 120 Ohm resistor that is included with the Miniserver.Īfter switching on the power supply, the Extensions first flash red, and after successful connection to the Miniserver they flash orange. This allows a maximum length of 500m/1640ft. The blue/white pair of a CAT5/6/7 cable is used to wire the Link throughout a building. If any of the Extensions are connected to a separate power supply, then all power supply's GND (negative) have to be interconnected. Up to 30 Extensions can be connected to a Miniservers Link Interface according to the following diagram:Ĭonnect the Extensions to a Miniserver by daisy-chaining the Link interfaces. Then follow the instructions for the Initial Setup to create your new project with the Miniserver.
#Loxone miniserver knx password#
The factory settings for user and password are: admin/admin You can then search for the Miniserver in Loxone Config and connect. If both Miniserver and computer are set to DHCP, they will use a .x link-local address.Īlternatively, you can manually assign a static IP address to the Miniserver and computer to enable a direct connection. If there is no DHCP server in your network, or if the Miniserver is connected directly to a PC, link-local addressing via Zeroconf is supported. The right LED indicates whether any System Status messages are available.Īt first startup with factory settings, the Miniserver is assigned an IP address by the router via DHCP. Once the boot up process is complete, the left status LED will blink green once every second.

The Miniserver starts after the power supply is turned on, and will be operational within a few seconds. Information on connecting additional devices. Via the LAN port the Miniserver is connected to the local network or a WiFi router. The Miniserver is installed on a DIN rail in a suitable enclosure.Ĭonnect the power supply, as well as inputs/outputs and interfaces, if applicable. Up to 30 Extensions can be added to the Miniserver via the Link interface to add additional functions such as inputs, outputs or interfaces.Ī Loxone Tree interface is also integrated to connect sensors and actuators throughout the building.
#Loxone miniserver knx free#
It features 8 potential free relays, 8 digital inputs and 4 analogue inputs (0-10V).

The LAN interface is used for programming and the integrated web server allows the control of the system via a web interface or the Loxone App. The replaceable microSD card contains the operating system as well as the user programming and settings. The Loxone Miniserver serves as central control unit for all kinds of automation tasks.